facebookBecome a Fan!
 
HOME :: Detection and Testing :: Military and Government : Radiation Survey Meter Kit 2241

Radiation Response Kit 2241-2RK

Radiation detection kit model 2241 2RK

Call for Availability
Radiation Survey Kit 2241-2RK
- 2 Complete Detector Setups
- Auto-ranging Digital Display
- Display in CPM and mR/hr
- Model 44-9 Pancake Alpha Beta Gamma Detector -
ideal for frisking individuals & screening packages, vehicles, etc.
- Model 44-2 Gamma Scintillator Detector
- All items come in a rugged Pelican protective case
- Training Video Available - no extra charge, upon request
- 1 Year Factory Warranty
- Free Calibration Training Course
provided at the factory (2 - 3 days)
Response Kit 2241-2RK - includes:
- Model 2241-2 Detection Unit
- Model 44-9 Pancake Detector
- Model 44-2 Gamma Scintillator Detector
- Rugged Pelican protective case


Call for discounted government & law enforcement
& quantity pricing, or fax your RFQ/ITB

DETECTORS: Model 44-9 Pancake G-M, Model 44-2 Gamma Scintillator
DET1/DET2: A locking toggle switch to allow for quick change between two detector setups
CONNECTOR: Series "C" (others available on request)
AUDIO: Built in unimorph speaker with ON/OFF switch (greater than 60 dB at 2 feet)
ALERT/ALARM: Indicated by enunciator on display and audible tone
DISPLAY: 4 digit LCD display with 0.5"(1.3cm) high digits, separate enunciators for display units, alert, alarm, low battery, detector overload, counting overflow, and scaler counting
BACKLIGHT: Push-button to activate
RATEMETER: Can display in R/hr, Sv/hr, cpm, or cps when control switch is in RATEMETER position
DISPLAY RANGE: Auto ranging from 0.0 R/hr - 9999 R/hr; 0.000 Sv/hr - 9999 Sv/hr; 0 cpm - 999k cpm; or 0 cps - 100k cps
LINEARITY: Reading within plus or minus 10% of true value with detector connected
SCALER: Activated by push-button in handle (count time adjustable from 1 - 9999 seconds in 1 second intervals)
CALIBRATION CONTROLS: Accessible from front of instrument (protective cover provided)
HIGH VOLTAGE: Adjustable from 200 - 2500 volts
DISCRIMINATOR: Adjustable from 2 - 100 mV
OVERLOAD: Indicated by OVERLOAD on display (adjustable depending on detector selected)
RESET: Push-button to zero display, acknowledge and/or reset alarm
POWER: 2 each "D" cell batteries (housed in sealed compartment that is externally accessible)
BATTERY LIFE: Typically 200 hours with alkaline batteries (low battery indicated on display)
CONSTRUCTION: Cast and drawn aluminum with beige polyurethane enamel paint
TEMPERATURE RANGE: -4° F(-20° C) to 122° F(50° C) May be certified for operation from -40° F(-40° C) to 150° F(65° C)
SIZE: 6.5" (16.5 cm)H X 3.5" (8.9 cm)W X 8.5" (21.6 cm)L
WEIGHT: 3.5 lbs (1.6 kg) including batteries

The following parameters are adjusted by removable switchboard. Once initial setup and calibration have been completed the switchboard can be removed without affecting normal operation of the instrument (Model 2241-2 may be ordered without switchboard)
BACKLIGHT "ON" TIME: 5, 30, 60, 90, 180, or 240 seconds for the backlight to stay "ON" when activated.
SET MINIMUM DISPLAY: Allows lower limit of auto-ranging display to be fixed. For example, display can be set to not show values less than 1 R/hr.
RS-232 DATA DUMP MODE: Enables or disables dump mode to RS-232 port. When enabled data will be dumped every 2 seconds
RS-232 DETECTOR SETUP MODE: Allows for detector parameters to be input by RS- 232 port
BAUD RATE: 150, 300, 600, 1200, 2400, 4800, 9600, or 19200 bps.
DEAD TIME: Adjustable from 0 - 9999 seconds
CALIBRATION CONSTANT: Adjustable from 0.001 - 280 X 109 counts/display unit
DISPLAY UNITS: Can read in R/hr, Sv/hr, cpm, or cps
TIME BASE: Can read in seconds or minutes
AUDIO DIVIDE: 1, 10, 100, or 1000 events-per-click
RESPONSE: FIXED: FAST response time adjustable from approximately 2 - 50 seconds. SLOW response is 5 times fast setting VARIABLE: Dependent on number of counts present. Typical times FAST - 4 - 25 seconds, SLOW - 4-60 seconds (All times stated from 10% to 90% of final reading)
RATEMETER ALERT/ALARM: Set at any point corresponding to pre-selected ratemeter range
SCALER ALARM: Adjustable from 1 - 999999 counts
SCALER COUNT TIME: Adjustable from 1 - 9999 seconds