Technical
features: Dimensions: Height - 76mm, Diameter
- 108mm, Weight - 323 g, Thread: NATO 40mm standard, EN
spec 148-1. Casing material: Reinforced impact resistant
polyamide
/ all stealth black nylon construction. Packaging: Sealed
with screw cap, inlet plug & outer bag. Shelf life:
A minimum of 10 years in when stored properly in original
packaging.
Manufactured
in a fully ISO 9001 certified facility. Special note: We
only sell new production filters, labeled as shown, avoid
purchasing from vendors who do not specialize in NBC gear.
We sell as many as 10,000 filters per month, therefore
we always have newly produced filters, which guarantee
the longest
shelf-life and are always in accordance with rapidly changing
requirements, regulations, materials & specifications.
For example, many vendors are selling M95 filters with “rainbow” stripe
stickers (3 color bands), which have been out of production
since 2001. Always work with a specialist in NBC gear, such
as ourselves, as changes in design are not always this easy
to identify. Your life may depend on the equipment you choose & the
information provided by your supplier.Click
here to read the history of HEPA filters
SCOTT NBC CANISTER - CHEMICAL WARFARE GAS PERFORMANCE TESTING
Tested by independent test labs to verify its performance against a range of
chemical agents.
DMMP
(surrogate for GB) 3000 mg/m3 50 lpm 0.04 mg/m3 >210 minutes*
Sarin (GB) 4000 mg/m3 32 lpm 0.04 mg/m3 >215 minutes*
Cyanogen Chloride (CK) 4000 mg/m3 32 lpm 8.0 mg/m3 30 minutes*
Chloropicrin (PS) 15000 mg/m3 30 lpm 0.7 mg/m3 70 minutes
Hydrogen Cyanide (AC) 5500 mg/m3 30 lpm 5.0 mg/m3 45 minutes
NIOSH
- Testing Conditions & Results - 42 CFR Part 84 Gases & Toxic
Industrial Materials.
Phosphine
(PH) 1500 ppm 64 lpm 0.3 ppm >24 minutes**
Tear Gas (CS) 3 ppm 64 lpm 0.05 ppm >480 minutes**
Tear Gas (CN) 16 ppm 64 lpm 0.05 ppm >480 minutes**
Chlorine (CL) 500 ppm 64 lpm 5.0 ppm >35 minutes**
Hydrogen Chloride (HC) 500 ppm 64 lpm 5.0 ppm 25 minutes**
Sulfur Dioxide (SD) 500 ppm 64 lpm 5.0 ppm >85 minutes**
Formaldehyde (FM) 100 ppm 64 lpm 1.0 ppm >100 minutes**
Ammonia (AM) 1000 ppm 64 lpm 50.0 ppm >55 minutes**
Methylamine (MA) 1000 ppm 64 lpm 10.0 ppm >80 minutes**
Hydrogen Sulfide (HS) 1000 ppm 64 lpm 10.0 ppm >60 minutes**
Chlorine Dioxide (CD) 500 ppm 64 lpm 0.1 ppm >60 minutes**
Hydrogen Fluoride (HF) 70 ppm 64 lpm 3.0 ppm >60 minutes**
* Note:
These tests are part of the performance specifications for
the C2A1 canister, as specified in military specification
MIL-PRF-51560A (EA), 1 July 1997, Performance Specification:
Canister, Chemical-Biological Mask: C2A1. The Enforcement
Cartridge meets or exceeds the performance requirements of
the C2A1 canister for these gases.
** Note: The Enforcement Cartridge toxic industrial materials (TIMs) performance
exceeds the 42 CFR Part 84 minimum service life requirements for these gases.
In addition to protecting against toxic industrial materials (TIMs) and the
chemical warfare agents listed above, the Enforcement Cartridge offers particulate
protection that is over 99.99% efficient. The P100 particle filter removes
all aerosols and solid particulates, which makes it effective protection against
a range of weaponized biological agents, down to 0.03 microns in diameter.
|